ID Date Author Event Time Type Section Icon Subject Status RTime (min) Text Attachments
  977   Wed 09 May 2012 01:03:49 Ekwarong Amornwittawat Tue 08 May 2012 11:15:40 Machine StudyRF Note Parameter calibration      
  976   Wed 09 May 2012 01:03:05 Ekwarong Amornwittawat Tue 08 May 2012 09:55:52 ProblemRF Note Trasistor S3M4 fault      
  975   Wed 09 May 2012 01:00:36 Ekwarong Amornwittawat Tue 08 May 2012 09:32:13 Machine StudyRF Note Power on SYN-RF      
  974   Wed 09 May 2012 00:59:44 Ekwarong Amornwittawat Tue 08 May 2012 09:22:52 Machine StudyRF Note Power off main oscillator 118 MHz      
  969   Mon 07 May 2012 22:52:50 Somkiat Wisaiphion Mon 07 May 2012 22:30:00 ProblemElectrical Note SYN-BM fault ( Main PS fault)Fixed     
  960   Mon 07 May 2012 22:42:57 Somkiat Wisaiphion Mon 07 May 2012 21:38:00 ProblemLINAC Note Gun grid bias errorFixed     
  956   Mon 07 May 2012 21:32:16 Somkiat Wisaiphion Mon 07 May 2012 21:00:00 ProblemVacuum Note Reset and clear all faultCompleted   Reset PWS-Pump
  
  955   Mon 07 May 2012 21:31:28 Somkiat Wisaiphion Mon 07 May 2012 20:48:00 ProblemElectrical Note Electricity System failureFixed110PWS-Pump fault (Pump stop)
  
  949   Mon 07 May 2012 21:27:25 Somkiat Wisaiphion Mon 07 May 2012 18:35:00 ProblemVacuum Note Reset and clear all faultFixed  Reset PWS-Pump
Reset and clear all fault
K.Bongkoch comes here for clear CDD-1
  
  948   Mon 07 May 2012 21:25:05 Somkiat Wisaiphion Mon 07 May 2012 18:14:00 ProblemElectrical Note Electricity failureFixed96 PWS-Pump fault (Pump stop)
Chiller (CH-1) surge - CDP-1 dry
running
  
  947   Mon 07 May 2012 21:20:45 Somkiat Wisaiphion Mon 07 May 2012 17:10:00 InstallationRF Note Dr.Nawin finish X-RAY measurementCompleted     
  945   Mon 07 May 2012 21:19:29 Somkiat Wisaiphion Mon 07 May 2012 09:00:00 InstallationRF Note Install X-RAY measurement by Dr.NawinUnder Process     
  931   Sun 06 May 2012 10:19:39 Sudjakom Jummunt Sun 06 May 2012 08:40:00 RepairRF Note IPA Fault   Stop Injection / IPA  Fault
2 times
Adjust Voltage of reflection at interlock
  
  929   Sun 06 May 2012 10:15:50 Sudjakom Jummunt Sun 06 May 2012 08:25:00 RepairRF Note Reset Tuner      
  928   Sun 06 May 2012 10:15:09 Sudjakom Jummunt Sun 06 May 2012 08:13:00 RepairRF Note IPA Fault   IPA Fault  10 times   
  916   Sat 05 May 2012 16:48:33 Ekwarong Amornwittawat Sat 05 May 2012 14:32:42 ProblemUtility Note DIW-STR INLET alarm    temp 32.38.
STR RF-FW ~ 10.8 kw.
STR RF-Reflec ~ 94.9w.
  
  915   Sat 05 May 2012 16:43:48 Ekwarong Amornwittawat Sat 05 May 2012 14:13:42 ProblemUtility Note DIW-STR INLET alarm   temp 32.33.
STR RF-FW ~ 10.4 kw.
STR RF-Reflec ~ 94w @ beam current
  
  914   Sat 05 May 2012 16:38:11 Ekwarong Amornwittawat Sat 05 May 2012 09:12:02 ProblemRF Note Test Run SYNFixed  test LINAC and SYN.
9:52 Stop test .
adjust L-STV-M1 from 2.7 A -->
  
  895   Fri 04 May 2012 19:59:20 Ekwarong Amornwittawat Fri 04 May 2012 19:51:59 ProblemRF Note Test Run SYN    test run SYN only for check SYN-RF
IPA 10 minutes.
IPA no fault.
  
  894   Fri 04 May 2012 19:55:52 Ekwarong Amornwittawat Fri 04 May 2012 19:48:37 ProblemRF Note SYN-RF Reset   RESET SYN-RF IPA by off main
circuit-breaker
 
  
  890   Fri 04 May 2012 19:20:36 Ekwarong Amornwittawat Fri 04 May 2012 18:46:22 ProblemRF Note SYN-RF IPA Fault   SYN-RF IPA Fault 12 times while injection
to 130mA.
  
  887   Fri 04 May 2012 19:15:24 Ekwarong Amornwittawat Fri 04 May 2012 18:10:13 ProblemElectrical Note Beam Dump   Beam Dump@58mA
 
Electrical incoming voltage sag from
  
  861   Wed 02 May 2012 20:16:26 Ekwarong Amornwittawat Wed 02 May 2012 20:01:38 ProblemMagnet Note S-BM-M FaultFixed  115% B - Fault - RESET   
  852   Wed 02 May 2012 16:49:29 Tewarit Praneetponkrung Wed 02 May 2012 15:33:06 ProblemElectrical Note Power on all systemFixed  - File "2012-02-14 Inj Fast
BM1290A"
  
  851   Wed 02 May 2012 16:47:01 Tewarit Praneetponkrung Wed 02 May 2012 15:15:02 ProblemElectrical Note Electricity is come to Electirc SubFixed  -Turn on all system again   
  850   Wed 02 May 2012 16:44:57 Tewarit Praneetponkrung Wed 02 May 2012 14:53:51 ProblemElectrical Note Electrical Incoming Voltage Failed from PEAFixed  Beam Dump @ 70 mA
- DIW - water Pump off
- Magnets Power Supply in SYN ,STR
  
  808   Sun 29 Apr 2012 08:23:43 Tewarit Praneetponkrung Sun 29 Apr 2012 08:07:16 ProblemElectrical Note Y-BM-M, Y-QF-M, Y-QD-M faultFixed     
  798   Sat 28 Apr 2012 14:08:30 Somkiat Wisaiphion Sat 28 Apr 2012 14:00:00 ProblemOther Note STR-DIW Temp   STR-DIW Temp 32.91 ํC (Exceed set
point 32.5 ํC )
  
  791   Sat 28 Apr 2012 08:15:58 Natthawut Suradet Sat 28 Apr 2012 08:14:43 ProblemControl Warning Disconnect CNT-SRV local area networkUnder Process   ถอดสาย lan เครื่อง
CNT-SRV ออก เพื่อทดสอบปัญหาเครื่อง
restart เอง
  
  790   Sat 28 Apr 2012 08:14:14 Natthawut Suradet Sat 28 Apr 2012 08:14:13 ProblemControl Reply Re: Swap IP of CNT-SRV to DLG-SRV2Under Process 

    

       
            
  
Accelerator Technology Division | Synchrotron Light Research Institute (Public Organization) | Powered by ELOG V3.1.1