Message ID: 6450     Entry time: Mon 13 May 2019 09:14:43
Author: Apiwat Pinyoyang 
Event Time:Sun 12 May 2019 14:40:51 
Type: Problem 
Section: Cryogenics 
Icon: Warning 
Subject: SMPW fault 
Status: Completed 
RTime (min): 343 

14:40 SOFB uncontrolable / SMPW fault / Reset >>> OK

15:00 Dump beam @ 96.4 mA / Reset SMPW

15:06 Warm up HBT, STR, SWLS, SMPW magnet, Open MPW gap

15:18 Start injection

15:35 S-SMPW-M fault (MPS waterflow failure) / Reset >>> OK

15:54 Re-injection

15:56 S-SMPW-M fault (MPS waterflow failure) / Reset >>> OK

16:40 All GV close / S7_VC1_ALM fault, SSMPW_VC1_ALM occured / Reset >>> OK

17:00 BM water tube has broken / Change tube >>> OK

18:30 Warm up all system

20:24 Start injection / No beam

20:26 Re-warm up all system

20:43 Start injection (Max rate = 9.7 mA/min)

21:02 Stop injection @ 150 mA

21:05 Set parameter for store and close MPW gap complete 

21:08 SOFB complete @ 148.8 mA