SLRI Machine Status Accelerator Operation Cryogenics
  Accelerator E-Logbook  Not logged in Accelerator E-Logbook
Message ID: 6332     Entry time: Mon 11 Mar 2019 20:25:44
Author: Nitisart Kumdee 
Event Time:Mon 11 Mar 2019 20:00:33 
Type: Beam Operation 
Section: Machine Operation 
Icon: Note 
Subject: Beam Injection  
Status: Completed 
RTime (min): 14 

19:40 Test run syn >>> OK (Isyn= 15 mA)

20:00 stop SOFB @ 63.52 mA

20:01 warm up HBT , set parameter for injection and open MPW gap

20.07 Start injection >> Beam dump @ 63.30 mA / S-BMP-M1 value different (Set = 20kV but Monitored = 0.0 kV)

20.08 Warm up STR, HBT

20.09 S-BM-M fault / Resset OK

20.14 Warm up STR, HBT,

20.25 Set parameter for injection

20.28 Start injecrtion -> no beam

          Check : S-QF-L1-SMPW and S-QD-L2-SMPW >> fault / Local reset

20.43 Start injection (max rate = 15 mA/min)

20:54 Stop injection @ 150 mA

20.55 Beam drop from 149 MA to 135 mA during set parameter for beam store / Unknown

20:56 Set parameter for beam store , close MPW gap completed

20:59 SOFB completed

Attachment 1: SOFB_2019-03-11-1959.PNG  167 kB  | Hide | Hide all
SOFB_2019-03-11-1959.PNG
Accelerator Technology Division | Synchrotron Light Research Institute (Public Organization) | Powered by ELOG V3.1.1